{"id":1756,"date":"2024-01-10T13:18:55","date_gmt":"2024-01-10T12:18:55","guid":{"rendered":"https:\/\/mda.at7media.digital\/?p=1756"},"modified":"2024-05-07T13:53:52","modified_gmt":"2024-05-07T11:53:52","slug":"pv-mda","status":"publish","type":"post","link":"https:\/\/mdautomation.at\/en\/pv-mda\/","title":{"rendered":"PV MDA"},"content":{"rendered":"<h2 class=\"wp-block-heading\">PV 1Achs Schwenksystem<\/h2><p>PV swivel system to optimise the solar yield in winter and extend the operating time in summer:<\/p><p>The PV tilt system represents an advanced technology in the field of photovoltaics that aims to maximise the efficiency of solar energy generation. In winter, it optimises solar yield by adjusting the tilt angle to maximise solar irradiation. In summer, on the other hand, it extends the operating time by adjusting the tilt angle in order to utilise the solar radiation during a longer day.<\/p><p>Positioning via potentiometer for angle measurement:<\/p><p>The system uses a potentiometer to accurately measure the tilt angle of the swivelling system. This positioning technology enables precise alignment of the solar panel in relation to the sun to ensure maximum light yield.<\/p><p>Adjustment of the angle with solar tracker and calendar function for plausibility checks:<\/p><p>An integrated solar tracker continuously adjusts the tilt angle of the photovoltaic modules to the position of the sun. This takes into account a calendar function that takes into account specific dates and times throughout the year. This enables a plausibility check to ensure that the tilt angle adjustments correspond to the seasonal changes and are optimised for the different sun paths.<\/p><p>Wind sensor for swivelling to the 0 degree position during storms:<\/p><p>To protect the system from strong winds, a wind sensor is integrated that recognises when the swivel system should be swivelled to a safe position of 0 degrees in the event of a storm. This safety measure serves to prevent damage to the system while ensuring optimum performance when weather conditions permit.<\/p><p>This advanced PV pivoting system demonstrates how technology and precision can be combined to maximise the efficiency of solar installations while protecting them from adverse weather conditions.<\/p><h2 class=\"wp-block-heading\">Product features:<\/h2><p>1 axis with two drives via synchronous shaft<\/p><p>Surface area up to 4*6m 4-6kWp<\/p><figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\"><figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1444\" height=\"2560\" data-id=\"1759\" src=\"https:\/\/mda.at7media.digital\/wp-content\/uploads\/2024\/01\/DSC_3563-scaled.jpg\" alt=\"\" class=\"wp-image-1759\" srcset=\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-scaled.jpg 1444w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-scaled-300x532.jpg 300w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-169x300.jpg 169w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-578x1024.jpg 578w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-768x1361.jpg 768w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-867x1536.jpg 867w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-1155x2048.jpg 1155w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3563-7x12.jpg 7w\" sizes=\"(max-width: 1444px) 100vw, 1444px\" \/><\/figure>\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1444\" height=\"2560\" data-id=\"1758\" src=\"https:\/\/mda.at7media.digital\/wp-content\/uploads\/2024\/01\/DSC_3562-scaled.jpg\" alt=\"\" class=\"wp-image-1758\" srcset=\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-scaled.jpg 1444w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-scaled-300x532.jpg 300w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-169x300.jpg 169w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-578x1024.jpg 578w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-768x1361.jpg 768w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-867x1536.jpg 867w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-1155x2048.jpg 1155w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3562-7x12.jpg 7w\" sizes=\"(max-width: 1444px) 100vw, 1444px\" \/><\/figure>\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"1444\" height=\"2560\" data-id=\"1757\" src=\"https:\/\/mda.at7media.digital\/wp-content\/uploads\/2024\/01\/DSC_3565-scaled.jpg\" alt=\"\" class=\"wp-image-1757\" srcset=\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-scaled.jpg 1444w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-scaled-300x532.jpg 300w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-169x300.jpg 169w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-578x1024.jpg 578w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-768x1361.jpg 768w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-867x1536.jpg 867w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-1155x2048.jpg 1155w, https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3565-7x12.jpg 7w\" sizes=\"(max-width: 1444px) 100vw, 1444px\" \/><\/figure><\/figure>","protected":false},"excerpt":{"rendered":"<p>PV 1Achs Schwenksystem PV Schwenksystem zur Optimierung der Solarausbeute im Winter und Verl\u00e4ngerung der Betriebszeit im Sommer: Das PV-Schwenksystem repr\u00e4sentiert eine fortschrittliche Technologie im Bereich der Photovoltaik, die darauf abzielt, die Effizienz der Solarenergiegewinnung zu maximieren. Im Winter optimiert es die Solarausbeute durch Anpassung des Neigungswinkels, um die Einstrahlung der Sonne zu maximieren. Im Sommer [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":1760,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[51],"tags":[],"class_list":["post-1756","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-projekte"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PV MDA - Website<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mdautomation.at\/en\/pv-mda\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PV MDA - Website\" \/>\n<meta property=\"og:description\" content=\"PV 1Achs Schwenksystem PV Schwenksystem zur Optimierung der Solarausbeute im Winter und Verl\u00e4ngerung der Betriebszeit im Sommer: Das PV-Schwenksystem repr\u00e4sentiert eine fortschrittliche Technologie im Bereich der Photovoltaik, die darauf abzielt, die Effizienz der Solarenergiegewinnung zu maximieren. Im Winter optimiert es die Solarausbeute durch Anpassung des Neigungswinkels, um die Einstrahlung der Sonne zu maximieren. Im Sommer [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mdautomation.at\/en\/pv-mda\/\" \/>\n<meta property=\"og:site_name\" content=\"Website\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-10T12:18:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-05-07T11:53:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1444\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"md_wels_at7media\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"md_wels_at7media\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/\"},\"author\":{\"name\":\"md_wels_at7media\",\"@id\":\"https:\/\/mdautomation.at\/#\/schema\/person\/c084d17b61183c0c725486b6099d5c1a\"},\"headline\":\"PV MDA\",\"datePublished\":\"2024-01-10T12:18:55+00:00\",\"dateModified\":\"2024-05-07T11:53:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/\"},\"wordCount\":290,\"publisher\":{\"@id\":\"https:\/\/mdautomation.at\/#organization\"},\"image\":{\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg\",\"articleSection\":[\"Projekte\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/\",\"url\":\"https:\/\/mdautomation.at\/pv-mda\/\",\"name\":\"PV MDA - Website\",\"isPartOf\":{\"@id\":\"https:\/\/mdautomation.at\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg\",\"datePublished\":\"2024-01-10T12:18:55+00:00\",\"dateModified\":\"2024-05-07T11:53:52+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/mdautomation.at\/pv-mda\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#primaryimage\",\"url\":\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg\",\"contentUrl\":\"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg\",\"width\":2560,\"height\":1444},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/mdautomation.at\/pv-mda\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/mdautomation.at\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PV MDA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/mdautomation.at\/#website\",\"url\":\"https:\/\/mdautomation.at\/\",\"name\":\"Website\",\"description\":\"Hier kommt in K\u00fcrze eine neue Website\",\"publisher\":{\"@id\":\"https:\/\/mdautomation.at\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/mdautomation.at\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/mdautomation.at\/#organization\",\"name\":\"Website\",\"url\":\"https:\/\/mdautomation.at\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/mdautomation.at\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/mdautomation.at\/wp-content\/uploads\/2025\/03\/LOGO-MDAblueneu.png\",\"contentUrl\":\"https:\/\/mdautomation.at\/wp-content\/uploads\/2025\/03\/LOGO-MDAblueneu.png\",\"width\":3368,\"height\":1749,\"caption\":\"Website\"},\"image\":{\"@id\":\"https:\/\/mdautomation.at\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/mdautomation.at\/#\/schema\/person\/c084d17b61183c0c725486b6099d5c1a\",\"name\":\"md_wels_at7media\",\"url\":\"https:\/\/mdautomation.at\/en\/author\/md_wels_at7media\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PV MDA - Website","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mdautomation.at\/en\/pv-mda\/","og_locale":"en_US","og_type":"article","og_title":"PV MDA - Website","og_description":"PV 1Achs Schwenksystem PV Schwenksystem zur Optimierung der Solarausbeute im Winter und Verl\u00e4ngerung der Betriebszeit im Sommer: Das PV-Schwenksystem repr\u00e4sentiert eine fortschrittliche Technologie im Bereich der Photovoltaik, die darauf abzielt, die Effizienz der Solarenergiegewinnung zu maximieren. Im Winter optimiert es die Solarausbeute durch Anpassung des Neigungswinkels, um die Einstrahlung der Sonne zu maximieren. Im Sommer [&hellip;]","og_url":"https:\/\/mdautomation.at\/en\/pv-mda\/","og_site_name":"Website","article_published_time":"2024-01-10T12:18:55+00:00","article_modified_time":"2024-05-07T11:53:52+00:00","og_image":[{"width":2560,"height":1444,"url":"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg","type":"image\/jpeg"}],"author":"md_wels_at7media","twitter_card":"summary_large_image","twitter_misc":{"Written by":"md_wels_at7media","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/mdautomation.at\/pv-mda\/#article","isPartOf":{"@id":"https:\/\/mdautomation.at\/pv-mda\/"},"author":{"name":"md_wels_at7media","@id":"https:\/\/mdautomation.at\/#\/schema\/person\/c084d17b61183c0c725486b6099d5c1a"},"headline":"PV MDA","datePublished":"2024-01-10T12:18:55+00:00","dateModified":"2024-05-07T11:53:52+00:00","mainEntityOfPage":{"@id":"https:\/\/mdautomation.at\/pv-mda\/"},"wordCount":290,"publisher":{"@id":"https:\/\/mdautomation.at\/#organization"},"image":{"@id":"https:\/\/mdautomation.at\/pv-mda\/#primaryimage"},"thumbnailUrl":"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg","articleSection":["Projekte"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/mdautomation.at\/pv-mda\/","url":"https:\/\/mdautomation.at\/pv-mda\/","name":"PV MDA - Website","isPartOf":{"@id":"https:\/\/mdautomation.at\/#website"},"primaryImageOfPage":{"@id":"https:\/\/mdautomation.at\/pv-mda\/#primaryimage"},"image":{"@id":"https:\/\/mdautomation.at\/pv-mda\/#primaryimage"},"thumbnailUrl":"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg","datePublished":"2024-01-10T12:18:55+00:00","dateModified":"2024-05-07T11:53:52+00:00","breadcrumb":{"@id":"https:\/\/mdautomation.at\/pv-mda\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mdautomation.at\/pv-mda\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/mdautomation.at\/pv-mda\/#primaryimage","url":"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg","contentUrl":"https:\/\/mdautomation.at\/wp-content\/uploads\/2024\/01\/DSC_3564-scaled.jpg","width":2560,"height":1444},{"@type":"BreadcrumbList","@id":"https:\/\/mdautomation.at\/pv-mda\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/mdautomation.at\/"},{"@type":"ListItem","position":2,"name":"PV MDA"}]},{"@type":"WebSite","@id":"https:\/\/mdautomation.at\/#website","url":"https:\/\/mdautomation.at\/","name":"Website","description":"Hier kommt in K\u00fcrze eine neue Website","publisher":{"@id":"https:\/\/mdautomation.at\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mdautomation.at\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/mdautomation.at\/#organization","name":"Website","url":"https:\/\/mdautomation.at\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/mdautomation.at\/#\/schema\/logo\/image\/","url":"https:\/\/mdautomation.at\/wp-content\/uploads\/2025\/03\/LOGO-MDAblueneu.png","contentUrl":"https:\/\/mdautomation.at\/wp-content\/uploads\/2025\/03\/LOGO-MDAblueneu.png","width":3368,"height":1749,"caption":"Website"},"image":{"@id":"https:\/\/mdautomation.at\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/mdautomation.at\/#\/schema\/person\/c084d17b61183c0c725486b6099d5c1a","name":"md_wels_at7media","url":"https:\/\/mdautomation.at\/en\/author\/md_wels_at7media\/"}]}},"_links":{"self":[{"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/posts\/1756","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/comments?post=1756"}],"version-history":[{"count":1,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/posts\/1756\/revisions"}],"predecessor-version":[{"id":1761,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/posts\/1756\/revisions\/1761"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/media\/1760"}],"wp:attachment":[{"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/media?parent=1756"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/categories?post=1756"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mdautomation.at\/en\/wp-json\/wp\/v2\/tags?post=1756"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}